SuperLite II-XL 120 is a fire resistive, technically advanced glazing product that blocks radiant heat transfer to meet ASTM E119 requirements. SAFTI FIRST was the first to provide this new technology to the USA in 1982. SuperLite II-XL products have been tested to the stringent wall standard and therefore are considered a “transparent wall.” Fire resistive glazing allows for greater design flexibility while other fire protective glazing products, such as ceramics, are limited by code to interior applications of 45 minutes or less and to 25% of the wall area.
SuperLite II-XL, when used with an equally rated heat barrier framing system such as SAFTIfire™ GPX™, provides floor-to-ceiling and wall-to-wall design flexibility with unsurpassed clarity and the added benefit of sound reduction. These products provide the maximum life safety and property protection with unlimited design freedom. SuperLite II-XL products may be customized to meet bullet, blast and hurricane resistance, as well as enhanced energy performance.
- Maximum fire and impact safety with hose stream and full radiant heat protection.
- Largest tested and approved sizes up to 4,876 sq.in. in standard
1-1/2” profile. - Tint-free and optically clear. Perfect for property line requirements.
- Acoustical value of 44 STC.
- Available in custom architectural make-ups, such as laminated glass and energy-saving insulated units with NFRC certifications when used with GPX framing.
- 5 year warranty.
- USA manufactured for fast delivery and competitive pricing.
SuperLite II-XL Just Got Clearer!
Now available with ultra-clear Starphire® by PPG
| Fire Rating | Application | Max CV Area | Max CV W | Max CV H | Stops |
| 120 min. | Sidelites Windows Transoms Walls |
4,876 sq. in. | 124” | 124” | 5/8" |
Thickness: 1-1/2” (39mm) standard thickness
Weight: 12 lbs./sq. ft. in 1-1/2” (39 mm) standard profile
Sound Transmission Rating: STC 44 rating in 1-1/2” (39mm) standard profile
Fire Rating: 120 minutes with hose stream Meets ASTM E119 and
NFPA 251
Impact Safety Rating: CPSC 16 CFR 1201 Cat. I and II
NFRC Certifications with GPX Framing:
0.34 U-Factor when insulated with Solarban 60
0.27 SHGC when insulated with Solarban 60
55 Condensation Resistance when insulated with Solarban 60

| See Warranty |