Today, we offer the most comprehensive line of products in the industry:





Today, we offer the most comprehensive line of products in the industry:
Building codes limit safety wired glass rated 60-90 min. to 100 sq. in. in temperature rise doors due to radiant heat concerns. Please see SuperLite II-XL for sizes that exceed 100 sq. in.
SuperLite I-XL (20-60 min.) – Patented, medium-cost, CPSC Cat. I and II safety glazing with additional partial radiant heat protection. Free from tints or distortions and also available as IGU.
This product does not meet ASTM E119 and requires approval for 45-60 min. applications because it is fire tested without hose stream.
Building codes limit safety ceramics rated 60-180 min. to 100 sq. in. in temperature rise doors due to radiant heat concerns. Please see SuperLite II-XL for sizes that exceed 100 sq. in.
Building codes require ratings 60 minutes and above to meet ASTM E119. SuperLite II-XL can be used in 20-45 minute ratings if noise abatement or radiant heat protection is desired.
Please visit www.safti.com for further technical information or register for our educational program “Designing with Fire Rated Glass” (1 AIA LU/HSW credit).