Skip to content
  • QUOTE
  • 888.653.3333
  • info@safti.com
  • Products
    • Fire Protective Glass Tested to NFPA 252/257, UL 9/10C, ULC S104/S106; Blocks smoke and flames.
    • SuperLite® I
    • SuperClear® 45-HS
    • SuperClear® 45-HS-LI
    • SuperLite® I-XL
    • SuperLite® I-XL IGU
    • SuperLite® X-45/60/90
    • SuperLite® II-XL 45
    • Ceramics
    • Fire Resistive Glass Tested to ASTM E119 / UL 263 / ULC S101; Blocks smoke, flames and radiant heat.
    • SuperLite® II-XL 60
    • SuperLite® II-XL 90
    • SuperLite® II-XL 120
    • SuperLite® II-XLB 60
    • SuperLite® II-XLB 120
    • SuperLite® II-XLM 60
    • SuperLite® II-XLM 120
    • SuperSecure® II-XLS 45-120
    • Fire Rated Walls 60-120 minute fire resistive glass and frame assemblies tested to ASTM E119 / UL 263 / ULC S101.
    • GPX® Architectural Series Fire Resistive
    • GPX® Curtain Wall
    • GPX® Hurricane
    • GPX® Ballistic
    • GPX® Blast System
    • GPX® EZ Frame
    • Fire Rated Doors Full vision 20-45 minute fire protective doors and 60-90 minute temperature rise doors tested to NFPA 252 / UL 10C / ULC S104.
    • GPX® Architectural Series Fire Protective
    • GPX® Architectural Series Fire Resistive
    • GPX® Builders Series Fire Protective
    • GPX® Builders Series Temperature Rise
    • GPX® Hurricane
    • GPX® Ballistic
    • GPX® Vision Kit
    • Fire Rated Openings 20-45 minute fire protective glass and framing assemblies tested to NFPA 257 / UL 9 / ULC S106.
    • GPX® Architectural Series Fire Protective
    • GPX® Builders Series Fire Protective
    • GPX® EZ Frame
    • Fire Rated Floors 60-120 minute fire resistive glass floor assemblies tested to ASTM E119 / UL 263 / ULC S101.
    • GPX® FireFloor
    • Fire Rated Fences 20-60 minute fire rated glass fence for WUI areas or designated fire zones.
    • SAFTI FENCE
    • Specialty Glass
    • Laminated Safety Glass
  • Literature
  • Specs
  • Details
  • Videos
  • Resources
    About Us
    Videos
    Case Studies
    Articles
    Blogs
    Continuing Education
    Literature
    BIM Library
    Industry Links
    Press Releases
    Testimonials
    Technical Bulletins
    Newsletters
    Product Selector
  • Gallery
  • Contact
    Contact Us
    Meet Our Team
    Find Your Local Rep
    Request a Quote
  • Products
    • Fire Protective Glass
    • Fire Resistive Glass
    • Fire Rated Walls
    • Fire Rated Doors
    • Fire Rated Openings
    • Fire Rated Floors
    • Fire Rated Fences
  • Literature
  • Specs
  • Details
  • Videos
  • Resources
    • About Us
    • Product Selector
    • Articles
    • Blogs
    • BIM Library
    • Case Studies
    • Newsletters
    • Press Releases
    • Continuing Education
    • Literature
    • Technical Bulletins
    • Testimonials
    • Industry Links
    • Videos
  • Gallery
  • Contact
    • Contact Us
    • Meet Our Team
    • Find Your Local Rep
    • Request a Quote
Menu
  • Products
    • Fire Protective Glass
    • Fire Resistive Glass
    • Fire Rated Walls
    • Fire Rated Doors
    • Fire Rated Openings
    • Fire Rated Floors
    • Fire Rated Fences
  • Literature
  • Specs
  • Details
  • Videos
  • Resources
    • About Us
    • Product Selector
    • Articles
    • Blogs
    • BIM Library
    • Case Studies
    • Newsletters
    • Press Releases
    • Continuing Education
    • Literature
    • Technical Bulletins
    • Testimonials
    • Industry Links
    • Videos
  • Gallery
  • Contact
    • Contact Us
    • Meet Our Team
    • Find Your Local Rep
    • Request a Quote
Articles
Code Education
Article on the Hidden Risks and Costs of Using Sprinklers as an Alternate to 1-2 Hour Fire Resistive Glazing
Code Education

Article on the Hidden Risks and Costs of Using Sprinklers as an Alternate to 1-2 Hour Fire Resistive Glazing

BySAFTI FIRST Team
| May 31, 2017

Using Sprinklers as an Alternate to 1-2 Hour Fire Resistive Glazing

Before considering and alternate assembly that requires prior AHJ approval, read below.

Glazing that meets the ASTM E-119 standard are classified as “fire resistive” or “fire-resistance-rated” in Chapter 7 of the IBC. Marked with a “W”, it can be used as fire barriers in exit enclosures, exit passageways or horizontal exits to ensure that building occupants are protected from smoke, flames and dangerous radiant heat as they exit a burning building. In cases where evacuation is difficult or impossible (ex. immobile patients in hospitals or long-term care facilities), the fire barriers in exit enclosures, exit passageways or horizontal exits serve as areas of safe haven where building occupants can await rescue.

Given this important life safety function, the ASTM E-119 test is the most stringent and most difficult test to pass for all fire rated glazing assemblies – and rightfully so. The test specimen has to withstand temperatures of over 1800 degrees F without the passage of flame or gases hot enough to ignite cotton waste for the entire duration of the test; has to pass prescribed hose stream test; and has to limit the temperature rise on the non-fire side to less than 250 degrees F over ambient.

 

Hidden Risks and Costs of Using Sprinklers as an Alternate to 1-2 Hour Fire Resistive Glazing

 

So it surprising that a modified, less stringent version of the ASTM E-119 test now applies to special-purpose sprinklers used with fixed glazed assemblies as an alternative product for 1-2 hour fire resistive wall assemblies. Other than following the time and temperature curve, there is nothing that resembles the original ASTM E-119 test. There is no cotton waste test, there is no hose stream test, and there is no documented report showing how it limits the temperature rise on the non-fire side to less than 250 degrees F over ambient.

TYCO, a sprinkler manufacturer and proponent of the modified criteria, has capitalized on this sell its TYCO Model WS sprinkler system with heat strengthened or tempered glass as an alternative product in 1-2 hour fire resistive walls through ESR-2397. TGP, distributor of fire protective ceramics, has jumped in with TYCO to sell laminated ceramic with TYCO Model WS sprinklers as an alternative to 1-2 hour fire resistive walls.

In order to use the wetted-glass approach that TYCO and TGP are pushing, the architect must assume all the work and related costs for submitting the required documentation necessary for the AHJ to evaluate the TYCO Model WS and FireLite Plus WS as alternative products to ASTM E-119 rated fire resistive glazing. But before the architect or AHJ considers this alternative system, there are some important concerns that must be raised:

Documented Sprinkler Failure

The potential effectiveness of the TYCO Model WS and FireLite Plus WS systems is entirely dependent on 100% sprinkler reliability and effectiveness, which doesn’t exist. As the National Fire Protection Association (NFPA) has reported, sprinklers operated effectively only 87% of the time. In the same NFPA report, majority of sprinkler failures occurred because the system was shut off, and that majority of sprinkler ineffectiveness was because water did not reach the fire or not enough water was released. This could be caused by a number of factors, including manual tampering, lack of maintenance, low water pressure or damage to the system, which is a real possibility during natural disasters such as earthquakes.

Given this difference, how can an alternative ‘wall’ system that is entirely dependent on 100% sprinkler reliability – which does not exist per the NFPA’s report – be relied upon to provide the same level of protection that fire resistive glazing assemblies provide 24 hours a day, 7 days a week without the mechanical triggers that sprinklers need?

Questionable Radiant Heat Protection

In addition to sprinkler failure, another concern that should be raised is how the TYCO Model WS or FireLite Plus WS system limits radiant heat. Wetting the surface of heat-strengthened or tempered glass may prevent thermal shock and compartmentalize smoke and flames, but there is no documented evidence of limiting the passage of radiant heat to less than 250 degrees F over ambient. Ceramics may be able to resist cracking or shattering at high temperatures, but the IBC limits its use to fire protective applications only because it does not limit radiant heat whatsoever.

 

Hidden Risks and Costs of Using Sprinklers as an Alternate to 1-2 Hour Fire Resistive Glazing

 

Fact is, the only materials proven to limit the passage of radiant heat to less than 250 degrees F over ambient are fire resistive building materials that have successfully passed ASTM E-119 testing without any modifications to the test method or test assembly.

Allowing an alternative ‘wall’ that relies on sprinklers wetting the surface of heat-strengthened, tempered or ceramic glass to take the place of readily available, true ASTM E-119 tested, listed and labeled fire resistive glazing assembly means the risking the lives of building occupants that the code community serves to protect.

Cost Concerns

Somehow, there is a perception that the higher prices of fire resistive glazing compared to non-rated glazing is enough to consider TYCO Model WS and FireLite Plus WS as cost-effective alternatives. However, these alternative assembly uses a special wet-pipe sprinkler system that is different from the sprinklers used throughout the building. Per ESR-2397, the automatic water supply must have the capability of supplying 1 or 2 hours of water, depending on the rating of the wall. Depending on the circumstances, this can require larger pumps, increased water pressure and additional water that dramatically increases the initial cost of installing the system (more so if FireLite Plus is used, which is already expensive) and the perpetual maintenance costs required to make sure that the sprinkler system works.

This alternative ‘wall’ system could cost hundreds of thousands and dollars more over time compared to USA-made, competitively prices fire resistive glazing products that don’t need special wet-pipe sprinklers, has no maintenance costs and are potentially 20-50% cheaper than laminated ceramic.

Design Restrictions

Looking at ESR-2397 more closely shows several restrictions on the TYCO Model WS and FirePlus WS systems, including:

  • Maximum exposed glazing height of 13 feet. No horizontal mullions allowed.
  • 36” minimum pony wall required with heat-strengthened or tempered glazing.
  • 36” pony wall requirement waived when using FireLite Plus, its sheet size is restricted to 96”. With most floors having a typical height of 10 feet (120”), floor-to-ceiling glazing cannot be achieved without at least 2 feet (24”) of opaque wall.
  • Visible amber tint typical of all ceramics when using FireLite Plus WS.
  • Cannot be used in exterior wall applications where the fire separation distance is less than 10 feet for states following the 2009, 2012 and 2015 IBC (5 feet for states following the 2006 IBC).

None of these restrictions apply to 1-2 hour fire resistive glazing assemblies. Architects can have floor-to-ceiling, wall-to-wall glazing free from amber tints. Butt-glazed wall assemblies are also available for maximum transparency.

Hidden Risks and Costs of Using Sprinklers as an Alternate to 1-2 Hour Fire Resistive Glazing
Example of what an ESR-2397 assembly would look like after AHJ approval.
Hidden Risks and Costs of Using Sprinklers as an Alternate to 1-2 Hour Fire Resistive Glazing
Example of an already tested, listed and approved fire resistive assembly looks like without having to obtain AHJ approval

Of course, it is still up to the architect to decide if it is worth going through the alternative approval process for the TYCO Model WS or FireLite Plus WS products. At the same time, the AHJ still has the authority to either approve or reject these products based on IBC sections 104.10 and 104.1. What I hope to have accomplished through this blog is provide architects and AHJs with thoughtful pause on what fire resistive assemblies tested to ASTM E119 (without modifications to the test method or assembly) are supposed to do – 100% of the time, without failure. It’s a matter of life safety and occupant protection, after all.

Share:
PrevNext ArticleWhat Firefighters Can Teach Architects About Radiant Heat
Previous ArticleFire Door Requirements and Sprinkler ExceptionsNext
Back to Articles

Engineering. Design. Code.

Whether you’re looking for fire-rated walls, doors, openings, floors or a specialty service, we have the solution for you. With over 40 years of experience in testing, innovating, and providing technologically advanced fire-rated glass and framing products, we deliver unyielding performance and quality at a competitive price.

Let's Talk!

  • 888.653.3333
    (English)
  • 888.653.3333 ext. 652
    (Spanish)
  • info@safti.com
  • Representative Map
Contact
Phone
888.653.3333 - English
888.653.3333 ext. 652 - Spanish
Fax
888.653.4444
Email
info@safti.com
Address
Corporate
100 N Hill Dr, Ste12, Brisbane, CA 94005
Factory
220 S R Street, Merced, CA 95341

Sign up for our Newsletter!

Get notified of industry updates and new product alerts.

AFFILIATE COMPANIES
Division 5
1850 Grogan Ave, Merced, CA 95341
888.653.3333
Division 8
1891 Wardrobe Ave, Merced, CA 95341
866.848.2667
© 2025 SAFTI FIRST. All rights reserved.​
Disclaimer & Privacy Policy | Cookie Policy
Instagram Linkedin Facebook Youtube Vimeo
Suggested Pages
Case Studies
Request a Quote
SuperClear® 45-HS-LI
Continuing Education
Request a Quote
Continuing Education
Videos
SuperClear® 45-HS-LI
Case Studies
This website uses cookies to ensure you get the best experience on our website.

This website uses cookies to ensure you get the best experience on our website.


This website uses cookies to improve user experience. A cookie file is stored in your web browser and allows the website to recognize you and make your next visit easier and the website more useful to you. By using our website, you consent to all cookies in accordance with our Cookies Policy. Learn more.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage vendors Read more about these purposes
View preferences
{title} {title} {title}